Banner Engineering
Safety Light Curtain Products |
 |
|
|
|
|
1 |
Choose from 20 sizes in 150mm (6") increments two
resolutions
|
|
2 |
Option of mounting from each end or by mounting channel on
side
|
|
3 |
Diagnostic display, configuration switches, and zone
indicators (under access cover)
|
|
4 |
Security plate limits access and tampering with setup
configurations
|
|
5 |
Removable terminal blocks or quick-disconnect options
simplify wiring
|
|
|
|
-
Compact package is ideal for finger or hand detection on smaller
production machines, yet robust enough for larger power presses
-
Available in different sizes: 150 to 1200 mm (6" to 48") for 14 mm
resolution models or 150 to 1800 mm for 30 mm resolution models
-
14 mm resolution models have a range of 0.1 m to 6 m (4" to 20') and
30 mm resolution models have a range of 0.1 m to 18 m (4" to 60')
-
Bright display provides diagnostic information, indicates number of
beams blacked and identifies what beams are blocked
-
Reduced resolution (Floating Blanking), Trip or Latch Output,
External Device Monitoring (EDM), and Scan Code are DIP-switch
selectable
-
Compact, measuring only 36 mm x 45.2 mm (1.4" x 1.8")
-
Multiple mounting options and removable wire terminal blocks for
easy installation
A complete EZ-SCREEN system consists of an Emitter and Receiver.
Optional system components include interface modules and key-reset
switches. Banner also offers several system accessories which may be
useful, depending on your specific installation requirements. |
Download Literature
|
 |
|
|
|
|
1 |
Removable terminal blocks or quick-disconnect options
simplify wiring
|
|
2 |
Trip/Latch, External Device Monitoring (EDM), and scan
code settings (behind access port)
|
|
3 |
7-Segment display indicates specific error or
configuration condition
|
|
4 |
Models with 2, 3 or 4 beams, beam spacing from 300 to 584
mm (12" to 23")
|
|
5 |
Bright status indicators shows output and beam status
|
|
|
|
-
Economical 2-, 3-, or 4-beam, non-contact safety device offering
exceptional perimeter access guarding
-
Available in short range, 0.8 to 20 m (2.6' to 65') or long-range,
15 to 70 m (49' to 230')
-
Fast 24 millisecond output response time
-
Compact, measuring only 52 mm x 55 mm (2.0" x 2.2")
-
Multiple mounting options and removable wire terminal blocks for
easy installation
A complete EZ-SCREEN system consists of an Emitter and Receiver.
Optional system components include interface modules and key-reset
switches. Banner also offers several system accessories which may be
useful, depending on your specific installation requirements. |
Download Literature
|
 |
|
|
|
|
1 |
Removable terminal blocks or quick-disconnect options
simplify wiring
|
|
2 |
Trip/Latch, External Device Monitoring (EDM), and scan
code settings (behind access port)
|
|
3 |
7-Segment display indicates specific error or
configuration condition
|
|
4 |
Bright status indicators shows output status
|
|
5 |
Beam status indicator shows whether beam is aligned and
strength of signal
|
|
|
|
-
Economical single-beam, non-contact safety device offering
exceptional perimeter and access guarding
-
Available in short range, 0.8 to 20 m (2.6' to 65') or long-range,
15 to 70 m (49' to 230')
-
Fast 24 millisecond output response time
-
Compact, measuring only 52 mm x 55 mm (2.0" x 2.2")
-
Multiple mounting options and removable wire terminal blocks for
easy installation
A complete EZ-SCREEN system consists of an Emitter and Receiver.
Optional system components include interface modules and key-reset
switches. Banner also offers several system accessories which may be
useful, depending on your specific installation requirements. |
Download Literature
|
|
EZ-Screen
Accessories |
 |

|
-
Interface Modules provide isolated safety output contacts for a
Primary Safety Device (for example, an optical safety system or
safety control module) which has solid-state or relay contact
outputs and external device monitoring (EDM) capability.
-
Model IM-T-9A features three normally open 6 amp redundant-output
channels.
-
Model IM-T-11A features two normally open redundant-output channels
and one complementary (parallel) normally closed non-safety
auxiliary output channel, all rated at 6 amps.
-
Independent normally closed outputs for connection to the Primary
Safety Device’s monitoring input.
-
24V dc operation
-
22.5 mm (0.9") DIN-rail-mountable housing
-
Convenient plug-in terminal blocks
|
Download Literature
|
 |
|
- Compact housing meets IP65 requirements;can be mounted inside or
outside a control panel near the safeguard
- For use with EZ-SCREEN™ and PICO-GUARD OSSD outputs (Output
Signal Switching Device) or MINI-SCREEN®, MICRO-SCREEN®,
MACHINE-GUARD®, or other safety devices with hard relay contact
safety outputs(s)
- Monitors two or four redundant inputs to automatically suspend
the safety function of a safeguarding device or system during a
non-hazardous portion of a machine cycle
- Universal Safety Stop Interface (USSI) for connection of
supplemental safeguarding devices or E-stops
- Status LEDs and two-digit, seven-segment Diagnostic Display
indicate module status
|
Download Literature
|
|
|
|
|
-
Contactors provide an additional 10 or 16 amp current carrying
capability to any safety system
- Auxiliary contacts provide 3 or 4 additional contacts
- Suppressors extend the life of the actuating device (light
screen, two-hand control module, etc.)
- Modular construction for ease of assembly and installation
- Can be used with Banner's optical safety systems, two-hand
control modules and emergency-stop safety modules
- Safety Systems with Output Signal Switching Device (OSSD) will
use 24V dc Positively Guided Contactors, all other safety systems
can use 24V dc or 120V ac Positively Guided Contactors (depending on
application)
|
|
Positively Guided Contactor Models |
|
Description |
Model Number |
Voltage |
Contact
Configuration |
Contact Rating |
Positively Guided |
Used With |
Positively*
Guided
Contactors |
11-BG00-31-A12060
|
120V ac |
3 N.O.
&
1 N.C. |
10 amps |
– |
11-BGX10-40
11-BGX77-048 |
|
11-BG00-31-D-024 |
24V dc |
11-BGX10-40
11-BGX77-240 |
|
11-BF1601-12060 |
120V ac |
16 amps** |
–
|
11-G484-30
11-G318-48 |
|
11-BF16C01-024 |
24V dc |
11-G484-30
11-G477-240 |
|
Auxiliary Contacts |
11-BGX10-40 |
– |
4 N.O. |
– |
No |
11-BG Series |
|
11-G484-30 |
–
|
3 N.O.
|
–
|
Yes
|
11-BF Series
|
|
Suppressors
|
11-BGX77-048 |
48V dc |
– |
– |
– |
11-BG00-31-A12060 |
|
11-BGX77-240 |
125-240V ac
|
11-BG00-31-D024 |
|
11-G318-48 |
48V dc |
– |
– |
– |
11-BF1601-12060 |
|
11-G477-240 |
125-240V ac
|
11-BF16C01-024
|
*
Arc suppression is recommended.
**
N.C. contact is rated at 10 amps. |
|
 |
|
-
Rugged and compact light screen suitable for heavy-duty machine
guarding applications
-
Each system includes emitter(s), receiver(s), controller, and
interconnecting cables
-
12 Standard light screen heights from 114 mm to 1.2 m (4.5" to 4')
with either:
-
9 m (30') range with 19.1 mm (0.75") resolution*
-
18 m (60') range with 25.4 mm (1.00") resolution*
-
4
Heavy-duty light screen heights from 610 mm to 1829 mm (24" to 72")
with:
-
18 m (60') range with 38 mm (1.5") resolution*
-
All controllers feature floating blanking and selectable auto
power-up; other features (depending on model) include:
- Trip or latch outputs
- Fixed-beam blanking
- Muting
- One or two light screens per controller
- All components are FMEA tested to ensure control reliability,
and third-party certified to IEC 61496-1 and -2 (type 4)
- System design meets applicable requirements of CE, UL, and CSA
* Resolution assumes no blanking in use
- Explosion-proof and tubular sensor enclosures available
|
Heavy-Duty MINI-SCREEN Emitter & Receivers
Product Instruction Manual p/n 69018
(Rev. A) |
|
Download |
 |
Heavy-Duty MINI-SCREEN MSH Series Lens Shields
Product Data Sheet p/n 108622 |
|
Download |
 |
MINI-SCREEN MDSDINT-1T2 Replacement Boards
Product Data Sheet p/n 48227 |
|
Download |
 |
MINI-SCREEN MDSDINT-1T2/1L2 Dual DIN Controllers (Trip or Latch,
E-Stop Input)
Product Instruction Manual p/n 47297
(Rev. B) |
|
Download |
 |
MINI-SCREEN MSA Series Protective Mounting Brackets
Product Data Sheet p/n 64715 (Rev. A) |
|
Download |
 |
MINI-SCREEN MSA Series Replacement Power Supplies
Product Data Sheet p/n 41029 |
|
Download |
 |
MINI-SCREEN MSA Series Tubular Enclosures
Product Data Sheet p/n 109307 (Rev. A) |
|
Download |
 |
MINI-SCREEN MSA-RM-1 Relay Module
Product Data Sheet p/n 40842 |
|
Download |
 |
MINI-SCREEN MSA-RM-2 Relay Module
Product Data Sheet p/n 59664 |
|
Download |
 |
MINI-SCREEN MSCA-1, MSCB-1 & MSCT-1 Metal Box Controllers(Trip, 2 N.O.
Contacts)
Product Instruction Manual p/n 39022
(Rev. C) |
|
Download |
 |
MINI-SCREEN MSCA-1L2 Metal Box Controller (Latch, 2 N.O. Contacts)
Product Instruction Manual p/n 55702 |
|
Download |
 |
MINI-SCREEN MSCA-1S6 Metal Box Contr. (Trip/Latch, MSA-RM-6)-Addendum
to 39022
Product Instruction Manual p/n 65777
(Rev. B) |
|
Download |
 |
MINI-SCREEN MSCC Metal Box Controllers(DeviceNet,Muting)-Addendum to
67423/61409
Product Instruction Manual p/n 69336 |
|
Download |
 |
MINI-SCREEN MSCC-2L2M/2L3M Metal Box Controllers (Muting, Latch)
Product Instruction Manual p/n 61409 |
|
Download |
 |
MINI-SCREEN MSCC-2T2M/2T3M Metal Box Controllers (Muting, Trip)
Product Instruction Manual p/n 64723 |
|
Download |
 |
MINI-SCREEN MSCD-2 & MSCT-2 Metal Box Controllers (Trip, 2 N.O.
Contacts)
Product Instruction Manual p/n 47295 |
|
Download |
 |
MINI-SCREEN MSDINT-1 Replacement Boards
Product Data Sheet p/n 45291 |
|
Download |
 |
MINI-SCREEN MSDINT-1/1L2 DIN Controllers (Trip or Latch, No E-Stop
Input)
Product Instruction Manual p/n 44895
(Rev. C) |
|
Download |
 |
MINI-SCREEN MSS Series Lens Shields
Product Data Sheet p/n 44418 |
|
Download |
 |
MINI-SCREEN MUSF-DINT-1T2/1L2 Dual DIN Controllers (Trip or Latch, No
E-Stop)
Product Instruction Manual p/n 113482
(Rev. A) |
|
Download |
 |
MINI-SCREEN System (Daily Procedure)
Checkout Procedure p/n 39020 |
|
Download |
 |
MINI-SCREEN System (Semi-Annual Procedure)
Checkout Procedure p/n 39021 |
|
Download |
 |
MINI-SCREEN System with Muting (Daily Procedure)
Checkout Procedure p/n 62055 |
|
Download |
 |
MINI-SCREEN System with Muting (Semi-Annual)
Checkout Procedure p/n 60256 |
|
Download |
 |
|
|
|
 |

|
-
Banner MULTI-SCREEN Systems are micro-processor- controlled opposed
mode light screen systems which use two pairs of sensors to provide
point-of-operation guarding for two areas on the same machine
-
One control box operates two emitter/receiver sensor pairs: two
pairs of MINI-SCREEN® or MACHINE-GUARD™ sensors, or one pair of each
-
Features selectable one- or two-beam floating blanking; may also be
programmed for auto power-up
-
MULTI-SCREEN Systems consist of one control box, two sensor pairs
and four cables; all components are ordered separately
-
Control box automatically senses array length of each sensor pair
connected to it; no manual settings are required
-
Sensors are available with array lengths from 114 mm (4.5 in) to 1.8
m (72 in)
-
Separate alignment indicator for each sensor pair
-
FMEA tested to ensure control reliability
|
MULTI-SCREEN MUSA Series Replacement Power Supply
Product Data Sheet p/n 44230 |
Download |
 |
MULTI-SCREEN MUSA Series Replacement Transformer
Product Data Sheet p/n 44376 |
Download |
 |
MULTI-SCREEN MUSC-1/1T3 Dual Metal Box Controllers (Trip)
Product Instruction Manual p/n 42492
(Rev. B) |
Download |
 |
MULTI-SCREEN MUSC-1S6 Metal Box Contr. (Trip/Latch, MSA-RM-6)-Addendum
to 42492
Product Instruction Manual p/n 113681 |
Download |
 |
|
|
If you can't find what you are looking for
Call Us! or go to the
Banner Home Page
|
| |
|
Banner Safety Light Curtains
South Carolina Safety Products Distributor
Photoelectric Safety Products
|