Banner Engineering
Safety Interlock Products |
 |
|
-
Positive opening safety contacts (IEC 60947-5-1) (not dependent upon
springs)
-
Mechanically-coded actuators utilize two independent operating
elements to minimize intentional tampering or defeat
-
Rotating head allows actuator engagement from front or back or
either of two top positions
-
Choice of four standard actuators; special high extraction force
actuator is available as option
-
NEMA 4, IEC IP65 switch housing rating may be increased to NEMA 4X,
IEC IP67 with addition of screw to wiring chamber door
-
Insulated device (IEC 60947-5-1) on all models with plastic housings
|
Download Literature
|
 |
|
-
Positive opening safety contacts (IEC 60947-5-1); not dependent upon
springs)
-
Insulated device (IEC 60947-5-1) on all models with plastic housings
-
Protective Earth Terminal (IEC 60947-1) on all models with metal
housings
-
Models which have a separate actuator are keyed to discourage
intentional tampering or defeat
-
Industry standard limit switch housings: 100, 83, 40, and
low-profile 31 millimeter styles are available (EN 50041, EN 50047)
-
Models available with rotating actuators for hinged door
applications
-
Some models feature rotating actuator head
|
SI-LM40 Limit-Switch Style Safety Interlock Switches , In-line
Actuators (40 mm)
Product Data Sheet p/n 49372 (Rev. C) |
 |
Download |
 |
SI-LM40 Limit-Switch Style Safety Interlock Switches, Trumpet Actuator
(40 mm)
Product Data Sheet p/n 50159 (Rev. D) |
 |
Download |
 |
SI-LS31H Limit-Switch Style Interlock Switches, Hinged Lever Actuator
(31 mm)
Product Data Sheet p/n 50165 (Rev. C) |
 |
Download |
 |
SI-LS31R Limit-Switch Style Safety Interlock Switches, Rotary Actuator
(31 mm)
Product Data Sheet p/n 50163 (Rev. C) |
 |
Download |
 |
SI-LS83 and SI-LS100 Limit-Switch Style Safety Interlock Switches (83
& 100 mm)
Product Data Sheet p/n 59622 (Rev. D) |
 |
Download |
|
 |
|
-
Model series SI-LS42 (left) and SI-QM100 (right)
-
Positive opening safety contacts (IEC 60947-5-1); not dependent upon
springs)
-
Insulated device (IEC 60947-5-1) on all models with plastic housings
-
Protective Earth Terminal (IEC 60947-1) on all models with metal
housings
-
Choice of two locking mechanism types
-
Wide range of solenoid voltages available
|
SI-LS42 Locking Style Safety Interlock Switches
Product Data Sheet p/n 60099 (Rev. C) |
 |
Download |
 |
SI-QM100 Locking Style Safety Interlock Switches
Product Data Sheet p/n 49374 (Rev. C) |
 |
Download |
 |
|
 |
|
-
Non-contact safety interlock switches are the best choice for
washdown applications; the switch components are sealed and rated
NEMA 4X, IEC IP67
-
Tolerant of dirt buildup, sensing distance, and alignment
-
System consists of three components:
-
Coded magnet
-
Reed switch sensor
-
Controller module
-
Magnet contains several differently-polarized magnets, and sensor
contains pole-stable reed contacts to minimize possibility of defeat
-
Easy installation; can be concealed for added defeat resistance
-
Sensor reed switches provide diverse input to the controller module
-
Must be used with Gate Monitoring modules for safety applications:
|
|
SI-MAG Series Magnetic Style Safety Interlock Switches |
|
Magnet Sensor* |
Magnet
Sensor Cable Length |
Coded Magnet |
Switching Distance
 |
|
Min. ON |
Max. OFF |
 |
SI-MAG1SM
SI-MAG1SMCO |
 |
3 m
(10') |
SI-MAG1MM |
 |
3
mm (0.12") |
14
mm (0.55") |
SI-MAG1MMHF
SI-MAG1MM90** |
8
mm (0.31") |
16
mm (0.63") |
 |
|
SI-MAG2SM |
 |
3 m
(10') |
SI-MAG2MM |
 |
4
mm (0.16") |
8
mm (0.32") |
 |
|
SI-MAG3SM |
 |
3 m
(10') |
SI-MAG3MM |
 |
3
mm (0.12") |
7
mm (0.28") |
* 9
m (30') cables re available for magnet sensors by adding suffix "W/30"
to the model number of the cabled version (e.g., SI-MAG1SM W/30).
** Difference is in Direction of Approach. |
Download Literature
|
 |

|
-
Monitor one or two mechanical safety switches for a contact failure
or wiring fault
-
Two redundant output switching channels for connection to
control-reliable power interrupt circuits
-
Auto reset or monitored manual reset
-
Designed to meet standards UL991, EN1088, and EN954-1 (Safety
Category 2 or 4)
-
6
amp safety output contacts
-
Plug-in terminal blocks
-
See Safety Interlock section for both mechanical and magnetic switch
selection
|
Download Literature
|
 |

|
-
Monitors one magnetic safety switch for a contact failure or wiring
fault
-
One redundant switching channel
-
Auto reset
-
8
amp safety output contacts
-
Fixed terminal blocks
-
See Safety Interlock section for both mechanical and magnetic switch
selection
|
Download Literature
|
 |
|
-
Safety switch is integrated and encapsulated into a load-bearing
hinge, providing a high degree of protection from intentional defeat
- Switch components concealed inside the hinge are protected from
mechanical impact, providing superior performance to
actuator-activated safety switches
- Hinge operates to a full 180° range of motion; safety switching
point (guard-closed position) is adjustable over the full 0-180°
operating range
- When properly interfaced or used with an appropriate controller,
two SI-HG80DQD(R) switches can achieve safety category 4, per ISO
13949 (EN 954-1)
- Robust zinc die-cast housing is corrosion resistant
|
Download Literature
|
 |
|
|
|
|
1 |
STB Self-Checking Optical Touch Buttons
|
|
2 |
AT-FM-10K
|
|
3 |
AT-GM-13A and AT-HM-13A
|
|
4 |
AT-GM-11KM and AT-HM-11KM with muting
|
|
|
-
Simultaneous action of both hand controls generates an output
signal; if either hand is released, the output signal from the
DUO-TOUCH is cancelled and cannot be reestablished until both hand
controls have been released, and simultaneously actuated again
-
Redundant forced-guide (positive guided) output contacts are
monitored to prevent an output signal from occurring if a fault is
detected
-
AT-FM-10K, AT-GM/HM-13A and AT-GM/HM-11KM designed to meet Type IIIC
requirements of EN574; may be used with STB Series self-checking
optical touch buttons
-
AT-FM-2A designed to meet Type IIIB/IIIA requirements of EN574; may
be used with OTB Series optical touch buttons (available together as
a "kit")
-
Available in a variety of voltages
|
|
 |

|
-
Interface Modules provide isolated safety output contacts for a
Primary Safety Device (for example, an optical safety system or
safety control module) which has solid-state or relay contact
outputs and external device monitoring (EDM) capability.
-
Model IM-T-9A features three normally open 6 amp redundant-output
channels.
-
Model IM-T-11A features two normally open redundant-output channels
and one complementary (parallel) normally closed non-safety
auxiliary output channel, all rated at 6 amps.
-
Independent normally closed outputs for connection to the Primary
Safety Device’s monitoring input.
-
24V dc operation
-
22.5 mm (0.9") DIN-rail-mountable housing
-
Convenient plug-in terminal blocks
|
Download Literature
|
 |
|
- Compact housing meets IP65 requirements;can be mounted inside or
outside a control panel near the safeguard
- For use with EZ-SCREEN™ and PICO-GUARD OSSD outputs (Output
Signal Switching Device) or MINI-SCREEN®, MICRO-SCREEN®,
MACHINE-GUARD®, or other safety devices with hard relay contact
safety outputs(s)
- Monitors two or four redundant inputs to automatically suspend
the safety function of a safeguarding device or system during a
non-hazardous portion of a machine cycle
- Universal Safety Stop Interface (USSI) for connection of
supplemental safeguarding devices or E-stops
- Status LEDs and two-digit, seven-segment Diagnostic Display
indicate module status
|
Download Literature
|
|
|
|
|
-
Contactors provide an additional 10 or 16 amp current carrying
capability to any safety system
- Auxiliary contacts provide 3 or 4 additional contacts
- Suppressors extend the life of the actuating device (light
screen, two-hand control module, etc.)
- Modular construction for ease of assembly and installation
- Can be used with Banner's optical safety systems, two-hand
control modules and emergency-stop safety modules
- Safety Systems with Output Signal Switching Device (OSSD) will
use 24V dc Positively Guided Contactors, all other safety systems
can use 24V dc or 120V ac Positively Guided Contactors (depending on
application)
|
|
Positively Guided Contactor Models |
|
Description |
Model Number |
Voltage |
Contact
Configuration |
Contact Rating |
Positively Guided |
Used With |
Positively*
Guided
Contactors |
11-BG00-31-A12060
|
120V ac |
3 N.O.
&
1 N.C. |
10 amps |
– |
11-BGX10-40
11-BGX77-048 |
|
11-BG00-31-D-024 |
24V dc |
11-BGX10-40
11-BGX77-240 |
|
11-BF1601-12060 |
120V ac |
16 amps** |
–
|
11-G484-30
11-G318-48 |
|
11-BF16C01-024 |
24V dc |
11-G484-30
11-G477-240 |
|
Auxiliary Contacts |
11-BGX10-40 |
– |
4 N.O. |
– |
No |
11-BG Series |
|
11-G484-30 |
–
|
3 N.O.
|
–
|
Yes
|
11-BF Series
|
|
Suppressors
|
11-BGX77-048 |
48V dc |
– |
– |
– |
11-BG00-31-A12060 |
|
11-BGX77-240 |
125-240V ac
|
11-BG00-31-D024 |
|
11-G318-48 |
48V dc |
– |
– |
– |
11-BF1601-12060 |
|
11-G477-240 |
125-240V ac
|
11-BF16C01-024
|
*
Arc suppression is recommended.
**
N.C. contact is rated at 10 amps. |
|
|
| |
|
|


|
1 PICO-GUARD Controller
2 Attenuator
3 Straight Pair
4 Right-angle Pair
5 Active/Passive Pair
|
|
|
PICO-GUARD™ Fiber Optic Safety System directly
replaces mechanical safety interlock switches to safeguard potentially
dangerous machines. This unique combination of control-reliable,
non-contacting photoelectric and fiber optic technologies provides a
low-cost alternative to cumbersome and costly methods of machine
safeguarding. This revolutionary new concept in safety systems is
incredibly versatile, efficient and easy to install. It combines a
controller and various plug-in, snap-lock PICO-GUARD optical safety
interlock switches and plastic fiber optic cable to monitor doors,
gates, and hard guards.
A unique combination of control-reliable, non-contacting photoelectric
and fiber optic technologies
Incredibly flexible and easy to install
A low cost alternative to cumbersome and costly methods required for
machine safeguarding
Universal Safety Stop Interface (USSI) for connecting multiple
PICO-GUARD Controllers and other safety devices
Designed to meet ISO 13849 (EN954-1) Category 4 and IEC 61496-1 Type 4
requirements