Patented Autophase technology actually corrects
common wiring errors. Analog and network models
available. Click on the appropriate series to see details below...
...or select data sheets in PDF format from this list.
AutoPhase makes power transducer installation
simple.
There are over 40 ways to wire up a 3 phase, 4 wire
kW transducer. For example, reversing the orientation of a CT flips
the output waveform, tricking ordinary watt transducers into thinking
there is a 180 degree phase shift. Or if CT and voltage inputs are
mismatched, the transducer thinks there is a 120 degree phase shift.
Either way, you have a problem.
AutoPhase identifies the phases and polarity
automatically and corrects for the error in software. This eliminates
flashing "ERROR" lights, tedious and dangerous reconnecting of inputs.
AutoPhase even tells you which CTs are reversed and which phases are
mismatched!
AutoPhase is protected by US Patent 5,652,505
- Meter Grade Digital accuracy for reliable measurement.
- Advanced microprocessor running at 5 MIPS (faster than many
PCs!) provides high-speed sampling, accuracy and flexibility
impossible with traditional kW/kWH transducers.
- Accepts ProteCT Current Transformers with 0.333 V safe output...
Eliminates need for costly shorting blocks
- Accepts traditional current output (5 Amp) CTs... reuse your
existing CTs.
- Available as a bare circuit board (OEM Applications), Transducer
Module for mounting in your panel or pre-mounted in a NEMA-1 panel.
Get exactly what you need.
| Power Required |
None... Self-powered |
| Accuracy |
0.5% FS, True RMS Power |
| Voltage Range |
120-600 VAC, Auto Range Select, Up to 12 KV
with optional Potential Transformers |
| Amperage Range |
5-1500 Amps with ProteCTs
50-4000 Amps with Current Output CTs |
| Isolation Voltage |
3,700 VAC |
| Built-In Fuse rating |
600 VAC, 0.5A (No External fuses required) |
| Connections |
Voltage: 12" Leads, # 18 AWG, pre-tinned
Current Inputs & All Outputs: Captive screw terminal accept #
14-22 AWG wire |
| Analog Outputs |
Both available at all times |
| kW |
0-5 VDC or 0-10 VDC (User Selectable) Self
Powered, Opto Isolated, 10 KW Minimum Load impedance |
| kW |
4-20 mA, Self Powered 24VDC loop , Opto
Isolated, 500W Maximum Burden |
| Discrete Outputs |
Both available at all times |
| System Alarm |
Solid State N.O. Contact, 100mA @ 30 V AC/DC
(75, 80. 85 & 95% Undervoltage Setpoints) |
| kWH |
Solid State Contact, 100mA @ 30 V AC/DC,
Ranges 0.01, 0.1, 1.0 & 10 kWH per pulse |
| LCD Display |
Two Line, 16 Character |
| Environmental |
-18 to 50 C (0 to 122 F), 0-95% RH, NC |
| Dimensions |
Module: 9"Hx6.5"Wx2.6"D (23x16.5x6.5CM) NEMA1:
10"Hx10"Wx4"D(26x24x10CM) |
- Direct Modbus Connection with no expensive interface.
- Patented AutoPhaseTM Technology corrects common wiring errors
such as CT reversal and phase mismatch. This can save hours of field
labor!
- Meter Grade Digital accuracy.
- Advanced microprocessor running at 5 MIPS (faster than many
PCs!) allows measurement up to the 70th harmonic.
- Accepts ProteCT Current Transformers with 0.333 V safe output
that eliminates need for costly shorting blocks. Also accepts
traditional 5 Amp out CTs.
| Power Required |
None... Self powered |
| Accuracy |
0.5% FS, True RMS Power
+/- 0.5 Hz |
| Voltage Range |
120-600 VAC, Auto Range Select, Up to 12 KV
with optional Potential Transformers |
| Amperage Range |
5-1500 A with ProteCTs
50-10,000 A with Current Output (5A) CTs |
| Isolation Voltage |
3,700 VAC |
| Built In Fuse rating |
600 VAC, 0.5A (No External fuses required) |
| Connections |
Voltage: 12" Leads, # 18 AWG, pre-tinned
Current Inputs & All Outputs: Captive screw terminal accept #
14-22 AWG wire |
| Environmental |
-18 to 50 C (0 to 122 F), 0-95% RH, NC |
| Dimensions |
Module: 9"Hx6.5"Wx2.6"D (23x16.5x6.5CM)
NEMA1: 10"Hx10"Wx4"D(26x24x10CM) |
| Modbus Software Set |
RTU Version |
| Modbus Hardware Set |
RS485 Addressable, 9600 Baud |
| Optional |
RS 232 Point to Point, 9600Baud |
| Approvals |
UL and UL-C Listed |
Modbus Network Variables (All Values True RMS, 24
Points)
| |
FA |
FB |
FC |
Total |
| Voltage |
• |
• |
• |
| Amperage |
• |
• |
• |
| kW |
• |
• |
• |
• |
| kWH |
• |
• |
• |
• |
| kVA |
• |
• |
• |
| Power Factor |
• |
• |
• |
|
| Frequency |
• |
• |
• |
| CT Value |
|
|
|
• |
|